Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 15(19): 22959-22966, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37147771

RESUMO

A closed bipolar electrochemiluminescence (BP-ECL) platform for sensitive prostate specific antigen (PSA) detection was proposed based on a novel synergistic signal amplification strategy. Specifically, glucose oxidase-loaded Cu-based metal-organic frameworks (Cu-MOFs/GOx) as bifunctional probes were bridged on the anodic interface with the target PSA as the intermediate unit. In virtue of the large loading capacity of Cu-MOFs, a large amount of a co-reactant, i.e., H2O2 in this L-012-based ECL system and gluconic acid were generated on the anodic pole in the presence of glucose. The generated gluconic acid could effectively degrade the Cu-MOFs to release Cu2+ which greatly accelerates the formation of highly active intermediates from co-reactant H2O2, boosting the ECL intensity. As for the cathodic pole, K3Fe(CN)6 with a lower reduction potential is used to reduce the driving voltage and speed up the reaction rate, further strengthening the ECL intensity. Thanks to the synergistic signal amplification effect at both two electrode poles of the BP-ECL system, highly sensitive detection of PSA was realized with a detection limit of 5.0 × 10-14 g/mL and a wide linear range of 1.0 × 10-13-1.0 × 10-7 g/mL. The strategy provides a novel way for signal amplification in the BP-ECL biosensing field.


Assuntos
Técnicas Biossensoriais , Antígeno Prostático Específico , Humanos , Masculino , Medições Luminescentes , Peróxido de Hidrogênio , Imunoensaio , Técnicas Eletroquímicas , Limite de Detecção
2.
Biosens Bioelectron ; 195: 113651, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34562789

RESUMO

The photoelectrochemical (PEC) self-powered system has attracted great attention in disease detection. The determination of a simple and efficient approach for disease-related biomarkers is highly interesting and appealing. Herein, an ingenious visible light-induced membraneless self-powered PEC biosensing platform was constructed, integrating a signal amplification strategy for ultrasensitive split-type PEC bioanalysis. The system was comprised of a Bi2S3/BiPO4 heterojunction photoanode and a platinum (Pt) cathode in a one compartment chamber. An alkaline phosphatase (ALP)-loaded sandwich immunoassay was used to generate the signal reporter ascorbic acid (AA) in a 96-well plate, and myoglobin (Myo) was used as a model protein. In the presence of AA, ferrocene (Fc), and Tris (2-carboxyethyl) phosphine (TCEP), the chemical-chemical redox cycling scheme was operated upon the initial oxidation of Fc by the holes in the Bi2S3/BiPO4 photoelectrode, and Fc was regenerated from Fc+ by AA. Subsequently, AA was regenerated by TCEP after its oxidation, and cycling was triggered. As a result, the proposed self-powered PEC sensing exhibited excellent performance with a wide linear range from 5.0 × 10-13 to 1.0 × 10-7 g/mL, and a low detection limit of 2.0 × 10-13 g/mL for Myo. This work provided a new design of a redox cycling strategy in the self-powered PEC biosensor, and showed an effective approach for the clinical diagnosis.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Imunoensaio , Limite de Detecção , Oxirredução
3.
Anal Chem ; 93(28): 9920-9926, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34213883

RESUMO

To achieve high sensitivity for biomolecule detection in photoelectrochemical (PEC) bioanalysis, the ideal photoelectrode and ingenious signaling mechanism play crucial roles. Herein, the feasibility of the photogenerated hole-induced chemical-chemical redox cycling amplification strategy on a Z-scheme heterostructure photoelectrode was validated, and the strategy toward enhanced multiple signal amplification for advanced PEC immunoassay application was developed. Specifically, a direct Z-scheme Bi2S3/Bi2MoO6 heterostructure was synthesized via a classic hydrothermal method and served as a photoelectrode for the signal response. Under the illumination, the PEC chemical-chemical redox cycling (PECCC) among 4-aminophenol generated by the enzymatic catalysis from a sandwich immunoassay, ferrocene as a mediator, and tris (2-carboxyethyl) phosphine as a reducing agent was run on the Z-scheme Bi2S3/Bi2MoO6 heterostructure photoelectrode. Exemplified by interleukin-6 (IL-6) as the target, the applicability of the strategy was studied in a PEC immunoassay. Thanks to the multiple signal amplification originating from the high efficiency of the PECCC redox cycling system, the enzymatic amplification, and the fine performance of the Z-scheme Bi2S3/Bi2MoO6 heterostructure photoelectrode, the assay for IL-6 exhibits a very low detection limit of 2.0 × 10-14 g/mL with a linear range from 5.0 × 10-14 to 1.0 × 10-8 g/mL. This work first validates the feasibility of the PECCC redox cycling on the Z-scheme heterostructure photoelectrode and the good performance of the strategy in PEC bioanalysis. We envision that it would provide a new prospective for highly sensitive PEC bioanalysis on the basis of a Z-scheme heterostructure.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Bismuto , Imunoensaio , Limite de Detecção , Molibdênio , Oxirredução , Estudos Prospectivos
4.
Analyst ; 146(12): 3918-3923, 2021 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-33973589

RESUMO

Developing an efficient signal amplification strategy is very important to improve the sensitivity of bioanalysis. In this paper, a liposome-assisted enzyme catalysis signal amplification strategy was developed for electrochemiluminescence (ECL) immunoassay of prostate specific antigen (PSA) in a split-type mode. The sandwich immunoreaction occurred in a 96-well plate, and glucose oxidase (GOx) encapsulated and antibody-modified liposomes were used as labels. The ECL detection was carried out using a rGO-Au NP modified glassy carbon electrode (GCE). The large amount of generated H2O2, i.e. the coreactant of the luminol system, and the excellent catalytic behavior of rGO-Au NPs greatly boosted the ECL signal, resulting in the signal amplification. The developed ECL immunosensor for detecting PSA achieved a wider linear range from 1.0 × 10-13 to 1.0 × 10-8 g mL-1 and a detection limit of 1.7 × 10-14 g mL-1. The application of the proposed strategy was demonstrated by analyzing PSA in human serum samples with recoveries from 89.0% to 113.0%, and relative standard deviations (RSDs) were less than 6.6%. This work provides a new horizon to expand the application of liposomes for ECL bioanalysis.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Catálise , Técnicas Eletroquímicas , Ouro , Humanos , Peróxido de Hidrogênio , Imunoensaio , Limite de Detecção , Lipossomos , Medições Luminescentes , Masculino
5.
Anal Chim Acta ; 1106: 183-190, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32145847

RESUMO

Photoactive materials with high photo-electron transfer efficiency and stable signal output hold a key role in constructing the photoelectrochemical (PEC) biosensing systems. In this study, the ternary CdS@Au-g-C3N4 heterojunction was first prepared and characterized, and its application in PEC bioanalysis was explored. The gold nanoparticles sandwiched between CdS and g-C3N4, acting as both plasmonic photosensitizer and electron relay, significantly boosted the light absorption and accelerated the charge transfer from g-C3N4 to CdS, both of which contributed to the enhancement of photoelectric conversion efficiency. Signal quenching with graphene oxide-CuS efficiently weakened the photocurrent from CdS@Au-g-C3N4. The combination of the excellent PEC properties of CdS@Au-g-C3N4 and the remarkable quenching effects of graphene oxide-CuS enabled construction of a sandwich-type PEC immunosensor for prostate specific antigen (PSA) detection. This immunosensor achieved sensitive PSA analysis by multiple signal amplification mechanisms, with a detection limit of 0.6 pg mL-1 and a wide linear range from 1.0 pg mL-1 to 10 ng mL-1. This work not only demonstrates the great potential of noble metal sandwiched ternary heterojunctions in the PEC field, but also lays a foundation for developing the general PEC immunoassays.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Imunoensaio , Antígeno Prostático Específico/análise , Compostos de Cádmio/química , Cobre/química , Ouro/química , Grafite/química , Humanos , Compostos de Nitrogênio/química , Tamanho da Partícula , Processos Fotoquímicos , Sulfetos/química , Propriedades de Superfície
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 230: 118040, 2020 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-31931354

RESUMO

A high-efficient chemiluminescence (CL) platform for highly selective and sensitive H2S detection was constructed on the basis of the quenching effect of S2- on the copper ion modified graphitic carbon nitride nanosheets (Cu2+-g-C3N4 NSs) enhanced luminol-H2O2 system. Cu2+-g-C3N4 NSs with horseradish peroxidase-like catalytic activity were prepared and provide a great improvement for luminol-H2O2 system. The presence of S2- induced the formation of CuS precipitate on g-C3N4 NSs surface. The precipitate can block the catalytic Cu2+ sites on the g-C3N4 NSs surface, resulting in a great CL decrease of CL system. Based on such a mechanism, a simple, highly selective and sensitive CL biosensor for H2S detection was designed. Under the optimized conditions, luminol-H2O2-Cu2+-g-C3N4 NSs system gave a decrease of CL intensity with the Na2S concentration increasing. The CL biosensor is in a linear range of 10.0 pM-50.0 nM and the detection limit for detecting Na2S is as low as 2.0 pM. Moreover, the method here has enjoyed a successful application for determining H2S in human plasma samples and the recovery is between 95.7% and 110.0%.


Assuntos
Grafite/química , Sulfeto de Hidrogênio/sangue , Substâncias Luminescentes/química , Luminol/química , Nanoestruturas/química , Compostos de Nitrogênio/química , Técnicas Biossensoriais/métodos , Humanos , Peróxido de Hidrogênio/química , Limite de Detecção , Luminescência , Medições Luminescentes/métodos
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 219: 281-287, 2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31051422

RESUMO

A novel nitrogen and sulfur co-doped carbon dots (NS-CDs)-H2O2 chemiluminescence (CL) system was developed to detect carcinoembryonic antigen (CEA) by taking advantage of dual-signal amplification of functional Au@Ag nanoparticles (NPs) nanoprobes. Horseradish peroxidase (HRP) and the complementary DNA were co-immobilized onto Au@Ag NPs surface to shape the functional nanoprobes (HRP-Au@Ag-cDNA) for signal amplification. In this proposal, HRP-Au@Ag-cDNA was specifically hybridized with CEA aptamer-functionalized magnetic beads to form the double-strand hybridization nanocomposites (HRP-Au@Ag-dsDNA-MB). Upon the addition of CEA, the CEA aptamer preferred to bind with CEA instead of double-strand hybridization interaction, thus HRP-Au@Ag-dsDNA-MB was dehybridized and the HRP-Au@Ag-cDNA nanoprobe was released. The synergistic catalytic effects of HRP and Au @Ag NPs endow the nanoprobe producing a dual CL signal amplification in the NS-CDs-H2O2 CL system. The CL intensity of the developed strategy enhanced with CEA concentration increasing in the range of 0.3-80 ng mL-1. Benefiting from the synergistic effect, a detection limit as low as 94 pg mL-1 was obtained. Moreover, successful application of this CL sensing platform was achieved for the determination of CEA in human serum samples, demonstrating the promising prospect in the early tumor warning and therapeutic monitoring.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Carbono/química , Antígeno Carcinoembrionário/sangue , Peróxido de Hidrogênio/química , Ouro/química , Peroxidase do Rábano Silvestre/química , Humanos , Limite de Detecção , Medições Luminescentes/métodos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Nitrogênio/química , Prata/química , Enxofre/química
8.
Chem Commun (Camb) ; 54(7): 806-809, 2018 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-29313046

RESUMO

An ascorbic acid oxidase (AAO)-ascorbic acid bioevent-based electron donor consumption mode was introduced into the PEC bioassay for the first time. Ternary hybrid bismuth sulfide/silver sulfide/TiO2 nanotube arrays as the photoelectrode coupled with AAO attached to SiO2 as a dual signal quenching strategy were employed for sensitivity enhancement.


Assuntos
Ascorbato Oxidase/química , Ácido Ascórbico/química , Técnicas Biossensoriais , Técnicas Eletroquímicas , Elétrons , Nanotecnologia , Ascorbato Oxidase/metabolismo , Ácido Ascórbico/metabolismo , Bismuto/química , Nanotubos/química , Processos Fotoquímicos , Compostos de Prata/química , Sulfetos/química , Titânio/química
9.
ACS Appl Mater Interfaces ; 10(4): 3723-3731, 2018 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-29313657

RESUMO

The detection of biomarkers with high sensitivity and accuracy in real biosamples remains challenging. Herein, a universal spatial-resolved photoelectrochemical (PEC) ratiometry for biodetection of prostate-specific antigen (PSA) as model biomarker was designed for the first time based on a dual-electrode array modified by CdS@g-C3N4 heterojunction coupled with CuS quantum dots (QDs) as signal amplification tags. Specifically, a new kind of photoactive material, the CdS@g-C3N4 p-n heterojunction with high photoelectric conversion efficiency and good chemical stability, was synthesized and immobilized on two spatial-resolved electrodes (WE1 and WE2). After immobilizing gold nanoparticles and capturing PSA antibodies on the electrodes, WE1 incubated with various concentrations of PSA was taken as a working electrode, whereas WE2 with a fixed concentration of PSA was used as an internal reference electrode. Next, signal antibodies of PSA-labeled CuS QDs as PEC signal quenchers were immobilized on the electrodes to form a sandwich-type immunocomplex. With the aid of a multiplexed disjunctor, the PEC responses of the dual electrodes were recorded, and the PSA was quantified via the ratio values of photocurrent intensities from WE1 and WE2. Combining the fine PEC performance of the CdS@g-C3N4 heterojunction with the superior quenching effect of CuS QDs in the spatial-resolved platform, the ratiometric system exhibits a linear range from 1.0 × 10-11 to 5.0 × 10-8 g mL-1 with a limit of detection of 4.0 pg mL-1. The results demonstrated herein may provide a new pattern for biomarker detection with high accuracy and good specificity as well as satisfactory applicability in real biosamples.

10.
Biosens Bioelectron ; 99: 92-98, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-28743084

RESUMO

A novel and competitive electrochemiluminescence (ECL) aptasensor for prostate specific antigen (PSA) assay was constructed using gold nanorods functionalized graphene oxide (GO@AuNRs) multilabeled with glucose oxidase (GOD) and streptavidin (SA) toward luminol-based ECL system. A strong initial ECL signal was achieved by electrodeposited gold (DpAu) on the electrode because of gold nanoparticles (AuNPs) motivating the luminol ECL signal. The signal probes prepared by loading GOD and SA-biotin-DNA on GO@AuNRs were used for achieving multiple signal amplification. In the absence of PSA, the signal probes can be attached on the electrode by hybridization reaction between PSA aptamer and biotin-DNA. In this state, the GOD loaded on the probe could catalyze glucose to in situ produce H2O2 and then AuNRs catalyze H2O2 to generate abundant reactive oxygen species (ROSs) in luminol ECL reaction. Both the high-content GOD and AuNRs in the signal probe amplified the ECL signal in the ECL system. Moreover, the combination of SA with biotin-DNA further expands ECL intensity. The integration of such amplifying effects in this protocol endows the aptasensor with high sensitivity and good selectivity for PSA detection. This aptasensor exhibits a linear relation in the range of 0.5pgmL-1 to 5.0ngmL-1 with the detection limit of 0.17pgmL-1 (S/N = 3). Besides, the strategy was successfully applied in determination of human serum samples with recovery of 81.4-116.0%.


Assuntos
Técnicas Biossensoriais , Glucose Oxidase/química , Nanopartículas Metálicas/química , Antígeno Prostático Específico/isolamento & purificação , Aptâmeros de Nucleotídeos/química , Biotina/química , Ouro/química , Grafite/química , Humanos , Peróxido de Hidrogênio/química , Limite de Detecção , Nanotubos/química , Antígeno Prostático Específico/sangue , Estreptavidina/química
11.
Biosens Bioelectron ; 91: 246-252, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28013019

RESUMO

Herein, a novel photoelectrochemical (PEC) immunosensing platform for highly sensitive detection of prostate specific antigen (PSA) was constructed based on dual-quenching of photocurrent from CdSe sensitized TiO2 electrode by gold nanoparticles decorated dopamine-melanin nanospheres (AuNPs-Dpa-melanin CNSs). In this proposal, CdSe sensitized TiO2 was used as photoelectrochemical matrix and the functional AuNPs-Dpa-melanin CNSs were used as signal quenching element. The dual quenching of the gold nanoparticles decorated Dpa-melanin CNSs to the CdSe sensitized TiO2 was achieved as follows: (i) the strong energy transfer between the CdSe quantum dots (QDs) and Au NPs diminishes the photocurrent signal of CdSe QDs; (ii) the steric hindrance of AuNPs-Dpa-melanin CNSs partly obstructs the diffusion of the electron donor, i.e. ascorbic acid, to the surface of photoelectrode, which make the depleting efficiency of the photogenerated holes decrease, leading to a declined photocurrent intensity. On the basis of the dual quenching effect of AuNPs-Dpa-melanin CNSs, a competitive immunosensing platform for PSA was designed upon the specific binding of anti-PSA to PSA and PSA functionalized AuNPs-Dpa-melanin CNSs conjugates. This proposed immunosensor possesses wide linear range from 1.0×10-11gmL-1 to 1.0×10-7gmL-1 with the detection limit of 2.7pgmL-1. Moreover, the applicability of the present method was demonstrated in the determination of PSA in human serum. The strategy creates new paradigms for PSA and other tumor markers detection and demonstrates high sensitivity, good specificity, and satisfied applicability in complex biological samples.


Assuntos
Compostos de Cádmio/química , Técnicas Eletroquímicas/instrumentação , Ouro/química , Indóis/química , Nanopartículas/química , Polímeros/química , Antígeno Prostático Específico/sangue , Compostos de Selênio/química , Titânio/química , Anticorpos Imobilizados/química , Técnicas Biossensoriais/instrumentação , Eletrodos , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Melaninas/química , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Nanopartículas/ultraestrutura , Nanosferas/química , Nanosferas/ultraestrutura , Processos Fotoquímicos
12.
Zhongguo Zhong Xi Yi Jie He Za Zhi ; 36(3): 339-44, 2016 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-27236893

RESUMO

OBJECTIVE: To study the inhibitory effect of paeoniflorin (PAE) on TNF-α-induced TNF receptor type I (TNFR1)-mediated signaling pathway in mouse renal arterial endothelial cells (AECs) and to explore its underlying molecular mechanisms. METHODS: Mouse AECs were cultured in vitro and then they were treated by different concentrations PAE or TNF-α for various time periods. Expression levels of intercellular cell adhesion molecule-1 (ICAM-1) were detected in the normal group (cultured by serum-free culture media), the TNF-α group (cultured by 2-h serum-free culture media plus 6-h TNF-α 30 ng/mL), the low dose PAE group (cultured by 2-h PAE 0.8 µmo/L plus 6-h TNF-α 30 ng/mL), the middle dose PAE group (cultured by 2-h PAE 8 µmol/L plus 6-h TNF-α 30 ng/mL), the high dose PAE group (cultured by 2-h PAE 80 µmol/L plus 6-h TNF-α 30 ng/mL) with Western blot analysis. Nuclear translocation of transcription factor NF-κB (NE-κB) was detected in the normal group (cultured by serum-free culture media), the TNF-α group (cultured by 2-h serum-free culture media plus 45-mm TNF-α 30 ng/mL), and the high dose PAE group (cultured by 2-h PAE 80 µmol/L plus 45-min TNF-α 30 ng/mL) by immunofluorescent staining. Expression levels of the phosphorylation of extracellular signal-regulated (protein) kinase (ph-ERK) and p38 (ph- p38) were detected in the normal group (cultured by serum-free culture media) and the high dose PAE group (2-h PAE 80 µmol/L culture) by Western blot. NF-κB inhibitor-α (IκBα) protein expressions were detected in the normal group (cultured by serum-free culture media), the TNF-α group (cultured by 2-h serum-free culture media plus 30-min TNF-α 30 ng/mL), the high dose PAE group (cultured by 2-h PAE 80 µmol/L plus 30-min TNF-α 30 ng/mL), the p38 inhibitor group (SB group, pretreatment with SB238025 25 µmol/L for 30 min, then treated by PAE 80 µmol/L for 2 h, and finally treated by TNF-α 30 ng/mL for 30 min), the ERK inhibitor group (PD group, treated by PD98059 50 µmol/L for 30 min, then treated by PAE 80 µmol/L for 2 h, and finally treated by TNF-α 30 ng/mL for 30 min) by Western blot. RESULTS: Compared with the normal group, ICAM-1 protein expression levels obviously increased (P < 0.01). Compared with the TNFα group, ICAM-1 protein expression levels were obviously inhibited in the high dose PAE group (P < 0.05). Protein expression levels of ph-p38 and ph-ERK were obviously higher in the hIgh dose PAE group (P < 0.05). Compared with the normal group, IκBα protein expression levels obviously decreased in the TNF-α group (P < 0.01). Compared with the TNFα group, TNF-α-induced IκBα degradation could be significantly inhibited in the high dose PAE group (P < 0.01); the inhibition of PAE on IκBα degradation could be significantly inhibited in the SB group (P < 0.05). NF-κB/p65 signal was mainly located in cytoplasm in the normal group. NF-κB/p65 was translocated from cytoplasm to nucleus after stimulated by 45 min TNF-α in the TNF-α group, while it could be significantly inhibited in the high dose PAE group. CONCLUSIONS: PAE inhibited TNF-α-induced expression of lCAM-1. Its action might be associated with inhibiting TNFR1/NF-κB signaling pathway. p38 participated and mediated these actions.


Assuntos
Células Endoteliais/efeitos dos fármacos , Glucosídeos/farmacologia , Monoterpenos/farmacologia , NF-kappa B/metabolismo , Receptores do Fator de Necrose Tumoral/metabolismo , Transdução de Sinais/efeitos dos fármacos , Animais , Células Cultivadas , Células Endoteliais/citologia , Molécula 1 de Adesão Intercelular/metabolismo , Camundongos , Fator de Necrose Tumoral alfa/farmacologia
13.
PLoS One ; 9(7): e101504, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24991819

RESUMO

BACKGROUND: Both total astragalus saponins (AST) and it's main component astragaloside IV (ASIV) have been used in China as cardiovascular protective medicines. However, the anti-inflammatory activities that are beneficial for cardiovascular health have never been compared directly and the molecular mechanisms remain unresolved. This study was conducted to compare the inhibitory effects of these drugs on TNFα-induced cell responses, related signaling pathways, and the underlying mechanisms in mouse arterial endothelial cells. METHODOLOGY/PRINCIPAL FINDINGS: Real-time qRT-PCR was performed to determine the expression of cell adhesion molecule (CAM) genes. Immunofluorescent staining was used to detect the nuclear translocation of transcription factor NF-κB-p65. Western Blot analysis was used to identify TNFα-induced NF-κB-p65 phosphorylation, IκBα degradation, and caspase-3 cleavage. Cell surface proteins were isolated and TNFα receptor-1(TNFR1) expression was determined. The results suggest that both AST and ASIV attenuate TNFα-induced up-regulation of CAMs mRNA and upstream nuclear translocation and phosphorylation of NF-κB-p65. However, TNFR1-mediated IκBα degradation, cleavage of caspase-3 and apoptosis were inhibited only by AST. These differences in the actions of AST and ASIV could be explained by the presence of other components in AST, such as ASII and ASIII, which also had an inhibitory effect on TNFR1-induced IκBα degradation. Moreover, AST, but not ASIV, was able to reduce TNFR1 protein level on the cell surface. Furthermore, mechanistic investigation demonstrated that TNFR1-mediated IκBα degradation was reversed by the use of TAPI-0, an inhibitor of TNFα converting enzyme (TACE), suggesting the involvement of TACE in the modulation of surface TNFR1 level by AST. CONCLUSION: ASIV was not a better inhibitor than AST, at least on the inhibition of TNFα-induced inflammatory responses and TNFR1-mediated signaling pathways in AECs. The inhibitory effect of AST was caused by the reduction of cell surface TNFR1 level, and TACE could be involved in this action.


Assuntos
Astrágalo/química , Células Endoteliais/efeitos dos fármacos , Receptores Tipo I de Fatores de Necrose Tumoral/metabolismo , Saponinas/toxicidade , Transdução de Sinais/efeitos dos fármacos , Triterpenos/toxicidade , Animais , Apoptose/efeitos dos fármacos , Artérias/citologia , Astrágalo/metabolismo , Caspase 3/metabolismo , Células Cultivadas , Selectina E/genética , Selectina E/metabolismo , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Proteínas I-kappa B/metabolismo , Molécula 1 de Adesão Intercelular/genética , Molécula 1 de Adesão Intercelular/metabolismo , Camundongos , Inibidor de NF-kappaB alfa , Fosforilação/efeitos dos fármacos , Fator de Transcrição RelA/metabolismo , Fator de Necrose Tumoral alfa/farmacologia , Regulação para Cima/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...